Bench top LCR Meter  200khz, 100khz

Bench top LCR Meter


LCR-2200 20~ 200KHz     15025點,  0.1% Basic Accuracy

LCR-2100  50Hz-100kHz, 34 points 0.1% Basic Accuracy

 

 

Introductions:

LCR-2000 series is a high precision LCR meter with the latest technology and high density
Circuit design LCR tester, LCR-2000 series is the new generation LCR.
The performance of the instrument can replace the traditional mechanical power switch, using software
Control the power switch. Basic accuracy of 0.05%
Test stability can be more accurate than those of the United States.
LCR-2000 series LCR meter with 4.3-inch TFT LCD display and new interface system
It has an elegant appearance and is easy to operate. Some models integrate transformer testing capabilities,
This improves production and testing efficiency. Moreover, it provides various interfaces and good
Compatible with SCPI commands, the LCR-2000 series of LCR instruments can easily constitute a variety of
Testing system to meet various needs of inspection, production, technology and research and development.

 

Model

LCR-2100

50Hz-100kHz, 34 points

LCR-2200

20Hz-200kHz, 15025 points, 

   

Basic measurement accuracy (See details in technical specification)

LCRZ

0.05%  

DCR, turn ratio

0.1%

Calibration condition

Warm up time:≥ 30 s

Environment temperature:23±5ºC 

Signal voltage:0.3Vrms – 1Vrms

Zero clearing:after OPEN, SHORT  

Testing cable length:0 m

Test signal frequency

LCR-2100

50Hz-100kHz , 34points

LCR-2200

20Hz-200kHz, 15025 points

   

Signal source output impedance

Selectable 30Ω, 100Ω,  ±1% @1kHz

AC test signal level

Normal

10mV—2Vrms

(LCR-2100:

50mV—1Vrms)

Minimum resolution:10mV,

Accuracy:10% x setting voltage+2mV

100μA—20mArms

(TH2830:

500μA—10mA rms)

Minimum resolution:0.1mA

Constant level

20mV—1Vrms

(LCR-2100

100mV—500mVrms)

Minimum resolution:10mV

Accuracy:10% x setting voltage +2mV

200μA—10mArms

(LCR-2100

1mA—5mA rms)

Minimum resolution:0.1mA

DC bias voltage source

(LCR-2100 with no bias voltage source)

0V— ± 5V

Minimum resolution:0.5mV, Accuracy:1% x setting voltage +5mV

0mA—± 50mA

Minimum resolution:0.5μA

Transformer test parameters

Turn Ratio, Turns, Phase, L, C, Lk, Q, ACR, DCR, Balance, Pin Short

LCR test parameters

|Z|, |Y|, C, L, X, B, R, G, D, Q, θ, DCR

DCR display range

0.00001 Ω-999.999 MΩ

DCR polarity configuration

FIX, ALT

Turn ratio display range

1:0.001-1000:1

LCR parameters display range

|Z|, R, X      0.00001Ω — 99.9999MΩ

|Y|, G, B        0.00001μs — 99.9999s

C             0.00001pF —  9.99999F

L                0.00001μH —  99.9999kH

D               0.00001 —  9.99999

Q            0.00001 —  99999.9

θ(DEG)         -179.999º — 179.999º

θ(RAD)          -3.14159 — 3.14159

Δ%                   -999.999% — 999.999%

Measurement time (≥10 kHz)

Fast: 75 meas/sec(13ms), Medium:11 meas/sec(90 ms) Slow:2.7meas/sec(370 ms)

Equivalent circuit

Serial, Parallel

Range mode

Auto, Hold

Trigger mode

Internal, Manual, External, Bus

Average time

1-255

Zero clearing

Open, Short, Load

Arithmetical operation

Direct reading, ΔABS, Δ%

Delay time setting

0 -- 60.000s, 1ms steps

Comparator function

10 bins, BIN1~BIN9, NG, AUX

Bin count function

PASS, FAIL front panel or scan fixture LED display

Memory

100 groups of LCRZ instrument setting files

201 test result

Interface

Control interface

HANDLER or SCANNER

Communication interface

USB HOST, RS232C, RS485(option), GPIB(option)

Storage interface

USB DEVICE (U-disk storage or barcode scan)

 

Order information:

LCR-2100  100KHz LCR meter

LCR-2200  200KHZ LCR Meter

Comparison chart:

Model LCR-2100 LCR-2200
Basic accuracy  0.05% 0.05%
Test speed  13 Time/Second 13 Time/Second
Display screen  4.3 Inch TFT LCD Display  4.3 Inch TFT LCD Display
Test Voltage  50mV- 2V 50mV- 2V
Test Frequency 50Hz - 100KHz 20KHz -200KHz
Signal impedance  30/100  Ohm 30/100 Ohm