hand-held process calibrator 4-20mA

 

4-20mA process Calibrator with RTD


      

The NEW TecpelR CL-327A is a battery-powered, hand-held process calibrator that allows process technicians to simulate and source variables signals. Output signals including DC voltage, DC current, ohms, analog transmitters, thermocouple, RTD, frequency, pulse, Switch On-OFF, are widely used in measurement and calibration for industrial field and laboratory application, it is one of necessary tools used to test and calibrate industrial automation systems and instruments. Get your job done fast and get it done precisely at affordable price. Your right choice!

process calibrator 4-20mA, temperature calibration CL-327A

Process Calibrator CL-327A PACKAGING

general characteristics:

Process Calibrator CL-327A

general characteristics:

 

1, The basic accuracy of the output of up to 0.02%, the output is displayed as 6 digit 
2, The output functions: DC voltage, DC current, ohms, analog transmitters, thermocouple, RTD, frequency, pulse, Switch On-OFF
3, The DC current output, can provide 25 percent and 100 percent of manual stepping, automatic step and auto ramp output function
4, The thermocouple output, can provide high-precision automatic cold junction compensation, ℃ or ℉ temperature display
5, Outside with high-precision temperature probe, accuracy: ± 0.2 ℃
6, Large-screen LCD display multiple data can be displayed simultaneously: DC current and % values, thermocouples, temperature values of thermal resistance and the corresponding indexing values, etc.
7, The operating performance is superior keyboard configuration, set the value corresponding to the output bit  setting change keys and LCD display.Working temperature and humidity
              0 to 50ºC, ≤80% RH non-condensing
              40 to 50ºC, ≤70% RH
Storage temperature and humidity
             -25 To 60ºC, ≤90% RH non-condensing
Display and backlight
              * Segment LCD dual display
              * White LED backlight
power supply
               * 4 x 1.5V AAA alkaline batteries
               * Automatic shutdown: can set auto-off time from 0 to 60 minutes
Size and Weight
              205 × 95 × 42 (mm), approximately 500g


Function

Reference

Range

Resolution

Accuracy

Remark

Thermocouple

R

0℃~1767℃

1℃

0~100℃:1.5℃

By using ITS-90 temperature scale;The accuracy does not include the error of internal temperature compensation caused by a sensor;

100~1767℃:1.2℃

S

0℃~1767℃

1℃

0~100℃:1.5℃

100~1767℃:1.2℃

B

600℃~1820℃

1℃

600~800℃:1.5℃

800~1820℃:1.1℃

E

-200.0℃~1000.0℃

0.1℃

-200.0~-100.0℃:0.6℃

-100.0~600.0℃: 0.5℃

600.0~1000.0℃: 0.4℃

K

-200.0℃~1372.0℃

0.1℃

-200.0~-100.0℃: 0.6℃

-100.0~400.0℃: 0.5℃

400.0~1200.0℃: 0.7℃

1200.0~1372.0℃: 0.9℃

J

-200.0℃~1200.0℃

0.1℃

-200.0~-100.0℃: 0.6℃

-100.0~800.0℃: 0.5℃

800.0~1200.0℃: 0.7℃

T

-250.0℃~400.0℃

0.1℃

-250.0~400.0℃:0.6℃

N

-200.0℃~1300.0℃

0.1℃

-200.0~-100.0℃: 1.0℃

-100.0~900.0℃: 0.7℃

900.0~1300.0℃: 0.8℃

L

-200.0℃~900.0℃

0.1℃

-200.0~0.0℃:0.7℃

0.0~900.0℃:0.5℃

U

-200.0℃~600.0℃

0.1℃

-200.0~0.0℃:0.7℃

0.0~600.0℃: 0.5℃

 

Download English manual of process calibrator CL-327A 4-20mA

 

Go To calibrators