This mode is discontinued.

TECPEL DCM-042 a high high resolution AC/DC clamp meter. With the resolution of 0.l. This current clamp meter is a great tool for PWM trouble shootingand in noisy environment measurment. Inrush current(100mS) mode is very helpful for measuring start current to check motors, lighting equipment and etc., th

Tis current clamp transmitter is a great meter for circuit measurement or for car applications.eatures :

Clamp meter DCM-042

Features of Clamp meter DCM-042

600A DC/AC True RMS Industrial Clamp Meter

  • Maximum reading of 9999
  • ACA/DCA measurement up to 600.0A
  • Inrush current (100mS) mode, for measuring start current for motors, lighting, etc.
  • Good for PWM trouble shooting and in Noisy environment measurement
  • Improved low current measurement accuracy
  • Temperature Compensation Current sensor
  • HOLD/PEAK HOLD, MAX/MIN, A-Hz and V-Hz function
  • Auto shut-off maximizes battery life
  • Large, backlit display easy to see
  • Dimensions of conductor: O35mm
  • EN61010-1 Approval. Over-Voltage Category CAT III 1000V

 

SPECIFICATIONS        CE  Mark Safety Approval
  • AC/DC Current Clamp meter ( DCM-042)

    Specifications:

    AC Current (accuracy: at the center of CT)

    Range: 0 to 600.0A

    Accuracy: ±(2.0%rdg+5dgts) on 20Hz to 100Hz

    ±(6.0%rdg+5dgts) on 100Hz to 400Hz

    Resolution: 0.1A

    AC Voltage

    Range: 0 to 600.0V

    Resolution: 0.1V

    Accuracy: ±(1.0%rdg+5dgts) on 20 to 100Hz

    ±(6.0%rdg+5dgts) on 100 to 400Hz

    Input impedance: 1M?

    DC Current (accuracy: at the center of CT)

    Range: 0 to 600.0A

    Accuracy: ±(2.0%rdg+5dgts)

    Resolution: 0.1A

    DC Voltage

    Range: 0 to 600.0V

    Resolution: 0.1V

    Accuracy: ±(1.0%rdg+5dgts)

    Input impedance: 1M?

    Resistance (Autorange)

    Range: 0 to 999.9?, 1000 to 9999?

    Accuracy: ±(1.5%rdg+5dgts)

    Resolution: 0.1?/1?

    Frequency

    Range: 20 to 400.0Hz

    Resolution: 0.1Hz

    Sensitivity: 5Vrms TTL signal,

    ?5A @20 to 100Hz, ?10A @100 to 400Hz

    Accuracy: ±(0.5%rdg + 5dgts)

    Diode Test

    Accuracy: ±(3.0%rdg+3dgts)

    Resolution: 0.001V

    Test current: 0.2mA

    Test Voltage: <3.0V

    Continuity

    Audible indication: less than 30?

    Capacitance

    Range: 0 to 999.9µF

    Resolution: 0.1µF

    Accuracy: ±(5.0%rdg + 10dgts)

    Temperature (K-Type Thermocouple)

    Range: -40°C to 1200°C, -40°F to 2200°F

    Accuracy: ±(0.5%rdg+1°C)

    ±(0.5%rdg+2°F), (not including thermocouple error)

    Resolution: 0.1°C on -40°C to 999.9°C

    1°C on 1000°C to 1200°C

    0.1°F on -40°F to 999.9°F

    1°F on 1000°F to 2200°F



     

Manual

 

 