Your Reliable and Promising Partner
Notice: This model is discontinued. Nov.21, 2013.
Model: FG 15 | |
FEATURES : | |
Rotary menu driven pop up and down function for easy operation. | |
TTL output up to 90 MHz. | |
Low noise signal source | |
Optional 2GHz frequency counter | |
Triangle , Square, Sine ,TTL Sync out, Asymmetry, Ramp up ,Log waveforms and DC. | |
Duty cycle up to 15MHz for TTL ,resolution 0.1%. | |
Amplitude attenuation -60db | |
DM Information DATA SHEET | |
FUNCTION GENERATOR | ||
SPECIFICATIONS CE Mark Safety Approval | ||
FUNCTION GENERATOR
|
WAVEFORMS |
Triangle ,Square,Sine ,TTL Sync out,Asymmetry,Ramp up,Log Waveforms and DC. |
Function Output Range | 0.2 Hz ~ 15MHz | |
TTL Ouput Range | 0.2 Hz ~ 90MHz | |
Resolution | 4 digits | |
Symmetry/Duty Cycle | 20% to 80% up to 1MHz | |
40% to 60% up to 10MHz | ||
Impedance | 50 Ohm +/-5% | |
Amplitude | +/- 10V into open circuit | |
+/-5V into 50 Ohm | ||
DC Offset | +/-10V into open circuit ; +/-5V into 50 Ohm | |
Square Wave | Rise or Fall Time < 15nS at full amplitude (50 Ohm) | |
Aberrations | < 5% ov V p at full amplitude ( 50 Ohm) | |
Triangle Linearity Error | 99 % up to 100KHz | |
Sine Wave Distortion | < -30 dB when f < 2MHz | |
Sync Output
Sweep width |
TTL Logic clock 0.2Hz ~ 90MHz | |
Lin or Log During selecting Range | ||
Sweep Rate | 0.2 Hz ~ 100 Hz ( 5 sec to 10 m sec) | |
VCG Characteristics | Control range: Max input 0
to 1.8V DC for selecting range
Input Impedance: 2 K ohm +/- 1% | |
Function Output Protection | < 20 V Peak on " Function Out" terminals | |
|
||
FREQUENCY COUNTER |
RANGE | 0.2 Hz ~ 100MHz (
Standard)
100 MHz ~ 2 GHz ( Option) |
Accuracy | +/- 5 count + Time base error | |
Resolution | 4 digits for external counter ; 7 1/2 digits for external counter | |
LPF | Auto or Manual mode | |
Time Base | 36.864 MHz +/- 25 PPM (
23.5 deg C +/- 5 deg C)
Optional TCXO timebase ( +/- 2.5 ppm) | |
Attenuation | x 1 ( ATT off ) : x 20 (ATT on) | |
Sensitivity | Standard : 0.2 Hz ~ 75MHz/
-22 dbm @ 50 OHm typical : 76 M ~ 100MHz
/ -15 dbm @ 50 Ohm typical Option: 100M ~ 2 GHz/ -10 dbm @ 50 Ohm typical | |
|
||
DUTY CYCLE MEASUREMENT (TTL LEVEL ONLY) |
Resolution | 3 digits |
Accuracy | 3% + 10 counts 5Hz < f < 10 MHz | |
|
||
General |
Power source | AC 115/ 230V; 50 / 60 Hz |
Operating Temp | 0 to 40 deg C ; < 80 % RH | |
Storage Temp | -20 deg to 70 deg C | |
Dimensions: | 300 mm x 220 mm x 150 mm (
11.8" x 8.7" x 5.9 ") (Dx W x H)
| |
Accessories | Power Cord x 1 ; Instruction Manual x 1 | |
|
Click below for more information.
DM Information | DATA SHEET |
|