Propel Quality Measurement.
Oscilloscope GDS-1062A | Oscilloscope GDS-1102A | Oscilloscope GDS-1152A |
---|---|---|
|
GDS-1062A |
GDS-1102A |
GDS-1152A |
VERTICAL |
|||
Channels |
2 |
2 |
2 |
Bandwidth |
DC~60MHz(-3dB) |
DC~100MHz(-3dB) |
DC~150MHz(-3dB) |
Rise Time |
<5.8ns Approx. |
<3.5ns Approx. |
<2.3ns Approx. |
Sensitivity |
2mV/div ~ 10V/div (1-2-5 increments) |
||
Accuracy |
±(3% x |Readout| + 0.1 div + 1mV) |
||
Input Coupling |
AC, DC & Ground |
||
Input Impedance |
1MΩ±2%, ~15pF |
||
Polarity |
Normal & Invert |
||
Maximum Input |
300V (DC+AC peak), CATII |
||
Waveform Signal Process |
+ , - , x, FFT, FFTrms |
||
OffsetRange |
2mV/div ~ 50mV/div: ±0.4V |
||
Bandwidth Limit |
20MHz (-3dB) |
||
TRIGGER |
|||
Sources |
CH1 , CH2 , Line , EXT |
||
Modes |
Auto, Normal, Single, TV, Edge, Pulse Width |
||
Coupling |
AC , DC , LF rej. , HF rej. , Noise rej. |
||
Sensitivity |
DC ~ 25MHz: Approx. 0.5div or 5mV; |
||
EXT TRIGGER |
|||
Range |
±15V |
||
Sensitivity |
DC ~ 25MHz : ~ 50mV ; 25M ~ 150MHz : ~100mV |
||
Input Impedance |
1MΩ±2% , ~ 15pF |
||
Maximum Input |
300V (DC AC peak) , CATII |
||
HORIZONTAL |
|||
Range |
1ns/div ~ 50s/div (1-2.5-5 increments); ROLL : 250ms/div ~ 50s/div |
||
Modes |
Main, Window, Window Zoom, Roll, X-Y |
||
Accuracy |
±0.01% |
||
Pre-Trigger |
10 div maximum |
||
Post-Trigger |
1000 div |
||
X-Y MODE |
|||
X-Axis Input |
Channel 1 |
||
Y-Axis Input |
Channel 2 |
||
Phase Shift |
±3°at 100kHz |
||
SIGNAL ACQUISITION |
|||
Real-Time Sample Rate |
1GSa/s maximum |
||
Equivalent Sample Rate |
25GSa/s maximum |
||
Vertical Resolution |
8 Bits |
||
|
2 Mega Points maximum |
||
Acquisition Mode |
Normal, Peak Detect, Average |
||
Peak Detection |
10ns (500ns/div ~ 10s/div) |
||
Average |
2 , 4 , 8 , 16 , 32 , 64 , 128 , 256 |
||
CURSORS AND MEASUREMENT |
|||
Voltage Measurement |
Vpp ,Vamp ,Vavg ,Vrms ,Vhi ,Vlo ,Vmax ,Vmin ,Rise Preshoot/Overshoot ,Fall Preshoot/Overshoot |
||
Time Measurement |
Freq ,Period ,Rise Time ,Fall Time ,Positive Width ,Negative Width ,Duty Cycle |
||
Cursors Measurement |
Voltage difference between cursors (V) |
||
Auto Counter |
Resolution : 6 digits |
||
ADJUSTABLE PROBE COMPENSATION SIGNAL |
|||
FrequencyRange |
1kHz ~ 100kHz, 1kHz/STEP |
||
DutyCycleRange |
5% ~ 95%, 5%/STEP |
||
CONTROL PANEL FUNCTION |
|||
Autoset |
Adjust Vertical VOLT/DIV, Horizontal TIME/DIV, and Trigger level automatically |
||
Save Setup |
Up to 15 sets of measurement conditions |
||
Save Waveform |
15 sets of waveform |
||
DISPLAY |
|||
TFT LCD Type |
5.6 inch |
||
Display Resolution |
234(Vertically) x 320(Horizontally) Dots |
||
Display Graticule |
8 x 10 divisions |
||
Display Brightness |
Adjustable |
||
INTERFACE |
|||
USB Slave Connector |
USB1.1 & 2.0 full speed compatible |
||
SD Card Slot |
Image (BMP), waveform data (CSV), and setup (SET) |
||
POWER SOURCE |
|||
LineVoltageRange |
AC 100V ~ 240V , 48Hz ~ 63Hz , Auto selection |
||
MISCELLANEOUS |
|||
Multi-Language Menu |
Available |
||
Onscreen Help |
Available |
||
DIMENSIONS & WEIGHT |
|||
|
310(W) x 142 (H) x 140(D)mm, Approx. 2.5kg |
|