Your Reliable and Promising Partner

Tecpel Home page

  Tecpel test instruments
 

200 KHz LCR Meter  w/RS-232 Interface

Model : LCR-200

 

 

bench lcr meter

Model: LCR 200

FEATURES :
Measurement Parameters : Z , Ls , Lp , Cs , Cp , DCR , ESR , D , Q , and θ.

Test conditions : 100MHz , 120Hz , 1KHz , 10KHz , 100KHz , 200KHz Basic Accuracy 0.1% ; Test Voltage: 1Vrms , 250mVrms , 50mVrms , 1Vdc(DCR only)

DMM Functionalities
Dual LCD Display with LED backlit
Open/Short Calibration
Remote Binning capacity
Auto range/ Range hold selection
RS-232 Interface
 
  DM  Information                DATA  SHEET
   

         

 LCR 200 Precision LCR Instrument
SPECIFICATIONS        CE  Mark Safety Approval

TEST CONDITON

 

 

Frequency

100Hz/120Hz/1KHz/10KHz/100KHz/200KHz

Level 1V rms/250mVrms/50mVrms/1Vdc(DCR only)
Measurement Parameters  Z , Ls , Lp , Cs , Cp , DCR , ESR , D , Q , and θ.
Basic Accuracy 0.1%

PRIMARY PARAMETERS DISPLAY

Z AC Impedance
DCR DC Resistance
Ls Serial Inductance
Lp Parallel Inductance
Cs Serial Capacitance
Cp  Parallel Capacitance

SECONDARY PARAMETERS DISPLAY

 

 

θ  Angle Impedance
ESR Equivalent Series Resistance
D Dissipation Factor
Q Quality Factor

COMBINATIONS OF Display

Serial Mode Z-θ, Cs-D, Cs-Q, Cs-ESR, Ls-D, Ls-Q, Ls-ESR
Parallel Mode Cp-D, Cp-Q, Lp-D, Lp-Q

MEASUREMENT RANGE

Parameter Range
z 0.000 Ohm to 500.0 Ohm
L 0.030 uH to 9999 H
C 0.003 pF to 80.00 mF
DCR 0.000 Ohm to 500.0 M Ohm
ESR 0.000 Ohm to 9999 Ohm
D 0.000 to 9999
Q 0.000 to 9999
θ -180.0 degree to 180 degree
V 0.000mV to +/- 600.0V
ESR 0.000 Ohm to 9999 Ohm
D 0.000 to 9999
Q 0.000 to 9999
θ -180.0 degree to 180 degree
V 0.000mV to +/- 600.0V
I 0.000mA to +/- 2.000A

DC VOLTAGE MEASUREMENT

Range 2V, 20V, 200V and 600V
Resolution 1mV, 10mV, 100mV, 1V
Accuracy +/- (0.4% +3 digits)
input Impedance 1 M Ohm

AC CURRENT MEASUREMENT

Range 2A, 0.2A, 20mA and 2mA
Resolution 1mA, 10mA, 100mA, 1A
Accuracy +/-(0.8% +5 digits) @ 40 Hz ~ 1 kHz
Input Impedance 1M ohm

AC CURRENT MEASUREMENT ( True RMS)

Range 2A, 0.2A, 20mA and 2mA
Resolution 1mA, 10mA, 100mA, 1A
Accuracy +/-(0.8% +5 digits) @ 40 Hz ~ 1 kHz
Current Shunt 0.1 Ohm@ current > 20mA/ 10 Ohm@ current </= 20mA

CONTINUITY CHECK

Continuity Thresh hold 50 Ohm (Approximately)
Continuity Indicator Tone Buzzer
Input Protection 600 Ohm (max)

DIODE TEST MEASUREMENT

Test Current 2.5mA ( Typical)
Open Circuit Voltage 5.0V DC (NOMINAL)
Input Protection 600V (max)

DIODE TEST MEASUREMENT

Power source AC 110/ 220V +/- 10% ; 50 / 60 Hz
Operating Temp 0 to 40 deg C (Operating) ; < 85 % RH
Storage Temp -20 deg to 70 deg C

GENEARL

Dimensions: 300 mm x 220 mm x 150 mm ( 11.8" x 8.7" x 5.9 ") (Dx W x H)

 

Weight 4.5 kgs
Standard Accessories  (1). TL09C Kelvin Clips x 1 pc ( 2) Test Leads  x 1 pc     Power Cord x 1    ;  Instruction Manaul x 1
Optional Accessories   (3) TL09A SMD test Probe ( 4) TL 09B Component Fixturelcr meter component fixture

 

Click below  for more information.

DM  Information DATA  SHEET

 


 

 

 

 

 

 

TECPEL CO., LTD.

E-MAIL: sales@tecpel.com ; oka@oka.com.tw
Tel : 886 (2)2737-5866 FAX : (02)2737-3343
Web-site: http://www.tecpel.com; http://www.oka.com.tw

 


Tecpel-Product Guide       TECPEL - Home page        Tecpel-Prouduct Guide